Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
techtalk:ref:oil22 [2024/02/08 23:09] hippysmack ↷ Links adapted because of a move operation |
techtalk:ref:oil22 [2024/04/11 04:21] hippysmack [Measuring Output Volume (flow rate) of a Gerotor Oil Pump] |
||
---|---|---|---|
Line 2: | Line 2: | ||
====== REF: Oiling & Lubrication ====== | ====== REF: Oiling & Lubrication ====== | ||
====== Measuring Output Volume (flow rate) of a Gerotor Oil Pump ====== | ====== Measuring Output Volume (flow rate) of a Gerotor Oil Pump ====== | ||
+ | See also [[techtalk:ref:oil24|Measuring Feed Oil Volume (flow rate) of the -72 Gear Type Oil Pump]] in the Sportsterpedia. \\ | ||
\\ | \\ | ||
Disregarding variations in internal leakage, a positive displacement pump will discharge a specific volume of fluid per revolution. \\ | Disregarding variations in internal leakage, a positive displacement pump will discharge a specific volume of fluid per revolution. \\ | ||
Line 537: | Line 538: | ||
| 1991-1997 Oil Pump- Restrictions Video ((video by Hippysmack)) | | | 1991-1997 Oil Pump- Restrictions Video ((video by Hippysmack)) | | ||
- | |{{:video:oil_pump_flow_testing_video-_1991-1997_restricted_feed_test_by_hippysmack.mp4|}}| | + | |{{video:100-oil_pump_flow_testing_-_1991-1997_restricted_feed_test_by_hippysmack.mp4|}}| |
==== Static Pressure Testing ==== | ==== Static Pressure Testing ==== | ||
Line 607: | Line 608: | ||
| 1998-2006 Style Pump Video \\ Cam Port Stream Quality ((video by Hippysmack)) | | | 1998-2006 Style Pump Video \\ Cam Port Stream Quality ((video by Hippysmack)) | | ||
- | |{{:video:oil_pump_flow_testing_video-_1998-2006_return_inlet_test-_cam_port_flooded_w_sump_port_open_then_plugged_by_hippysmack.mp4|}}| | + | |{{video:100-oil_pump_flow_testing_-_1998-2006_return_inlet_test-_cam_port_flooded_w_sump_port_open_then_plugged_by_hippysmack.mp4|}}| |
---- | ---- | ||