Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
techtalk:ref:tools160 [2020/08/11 21:55] – [Dissecting the MityVac 8000] hippysmack | techtalk:ref:tools160 [2024/01/24 22:41] (current) – hippysmack | ||
---|---|---|---|
Line 1: | Line 1: | ||
[[: | [[: | ||
====== REF: Tools - 160 ====== | ====== REF: Tools - 160 ====== | ||
- | ====== | + | ====== |
- | + | See also in the Sportsterpedia; | |
- | ====== Vacuum Pump ====== | + | [[techtalk: |
+ | [[techtalk: | ||
+ | [[techtalk: | ||
+ | [[techtalk: | ||
A hand operated vacuum pump is a versatile tool that can be used to test a variety of automotive systems and perform a number of useful tasks. ((MityVac MV-8000 Operating Manual)) \\ | A hand operated vacuum pump is a versatile tool that can be used to test a variety of automotive systems and perform a number of useful tasks. ((MityVac MV-8000 Operating Manual)) \\ | ||
Line 19: | Line 22: | ||
- The pump can be connected into a vacuum circuit and used to measure existing amounts of vacuum, just as any vacuum gauge would be used. \\ When used this way, do not pump the handle, or incorrect readings may result. | - The pump can be connected into a vacuum circuit and used to measure existing amounts of vacuum, just as any vacuum gauge would be used. \\ When used this way, do not pump the handle, or incorrect readings may result. | ||
- The vacuum gauge can be useful for detecting a fluctuating vacuum supply or a leaky hose. | - The vacuum gauge can be useful for detecting a fluctuating vacuum supply or a leaky hose. | ||
+ | - It can be used to test vacuum operated petcocks. | ||
+ | - It can be used to keep a constant vacuum on a vacuum operated petcock to drain the fuel tank. | ||
+ | - On cases with oil seepage along the case half seal, a MityVac has been used to apply a vacuum to the breathers (in the heads) for an external sealer application. ((aswracing of the XLFORUM https:// | ||
===== Proper Care and Maintenance ===== | ===== Proper Care and Maintenance ===== | ||
- | + | Handle the vacuum pump carefully or the gauge accuracy may be affected. ((MityVac MV-8000 Operating Manual)) \\ | |
- | Handle the vacuum pump carefully | + | |
Silicone oil is suggested to lubricate the pump / O-rings if needed. \\ | Silicone oil is suggested to lubricate the pump / O-rings if needed. \\ | ||
DOT 5 brake fluid (silicone based) or vegetable salad oil can also be used as lubricant in absence of silicone oil. \\ | DOT 5 brake fluid (silicone based) or vegetable salad oil can also be used as lubricant in absence of silicone oil. \\ | ||
Line 28: | Line 33: | ||
====== Dissecting the MityVac MV-8000 ====== | ====== Dissecting the MityVac MV-8000 ====== | ||
- | |||
{{: | {{: | ||